Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Rev Inst Med Trop Sao Paulo ; 64: e63, 2022.
Article in English | MEDLINE | ID: covidwho-2109458

ABSTRACT

COVID-19 disease is spread worldwide and diagnostic techniques have been studied in order to contain the pandemic. Immunochromatographic (IC) assays are feasible and a low-cost alternative especially in low and middle-income countries, which lack structure to perform certain diagnostic techniques. Here we evaluate the sensitivity and specificity of eleven different IC tests in 145 serum samples from confirmed cases of COVID-19 using RT-PCR and 100 negative serum samples from blood donors collected in February 2019. We also evaluated the cross-reactivity with dengue using 20 serum samples from patients with confirmed diagnosis for dengue collected in early 2019 through four different tests. We found high sensitivity (92%), specificity (100%) and an almost perfect agreement (Kappa 0.92) of IC assay, especially when we evaluated IgG and IgM combined after 10 days from the onset of symptoms with RT-PCR. However, we detected cross-reactivity between dengue and COVID-19 mainly with IgM antibodies (5 to 20% of cross-reaction) and demonstrated the need for better studies about diagnostic techniques for these diseases.


Subject(s)
COVID-19 , Dengue , Antibodies, Viral , COVID-19/diagnosis , Dengue/diagnosis , Humans , Immunoassay/methods , Immunoglobulin G , Immunoglobulin M , SARS-CoV-2 , Sensitivity and Specificity
2.
Diagn Microbiol Infect Dis ; 101(2): 115344, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1303485

ABSTRACT

Ventilator associated pneumonia(VAP) is a severe complication that can lead to high mortality when not early identified or when therapy is delayed. The aim of this study was to evaluate procalcitonin(PCT) as a biomarker for VAP development. In total, 73 hospitalized patients with COVID-19 were analyzed. PCT levels greater than 0.975ng/mL were more related to VAP. No association was found for C-reactive protein (CRP). The results show that procalcitonin may be a pertinent biomarker for VAP diagnosis and can be a helpful tool for antibiotic withdrawal.


Subject(s)
Antimicrobial Stewardship/methods , COVID-19/diagnosis , Pneumonia, Ventilator-Associated/diagnosis , Procalcitonin/blood , Adult , Aged , Aged, 80 and over , Anti-Bacterial Agents/therapeutic use , Biomarkers/blood , COVID-19/complications , Female , Humans , Intensive Care Units , Male , Middle Aged , Pneumonia, Ventilator-Associated/complications , Pneumonia, Ventilator-Associated/drug therapy , ROC Curve , SARS-CoV-2 , COVID-19 Drug Treatment
3.
Int J Infect Dis ; 104: 320-328, 2021 Mar.
Article in English | MEDLINE | ID: covidwho-1065182

ABSTRACT

OBJECTIVES: The coronavirus disease 2019 pandemic increased global demand for personal protective equipment (PPE) and resulted in shortages. The study evaluated the re-use of surgical masks and respirators by analysing their performance and safety before and after reprocessing using the following methods: oven, thermal drying, autoclave, and hydrogen peroxide plasma vapour. METHODS: In total, 45 surgical masks and 69 respirators were decontaminated. Visual integrity, air permeability, burst resistance, pressure differential and particulate filtration efficiency of new and decontaminated surgical masks and respirators were evaluated. In addition, 14 used respirators were analysed after work shifts before and after decontamination using reverse transcription polymerase chain reaction (RT-PCR) and viral culturing. Finally, reprocessed respirators were evaluated by users in terms of functionality and comfort. RESULTS: Oven decontamination (75 °C for 45 min) was found to be the simplest decontamination method. Physical and filtration assays indicated that all reprocessing methods were safe after one cycle. Oven decontamination maintained the characteristics of surgical masks and respirators for at least five reprocessing cycles. Viral RNA was detected by RT-PCR in two of the 14 used respirators. Four respirators submitted to viral culture were PCR-negative and culture-negative. Reprocessed respirators used in work shifts were evaluated positively by users, even after three decontamination cycles. CONCLUSION: Oven decontamination is a safe method for reprocessing surgical masks and respirators for at least five cycles, and is feasible in the hospital setting.


Subject(s)
COVID-19/prevention & control , Decontamination/methods , Masks/virology , Pandemics , Personal Protective Equipment/virology , SARS-CoV-2/isolation & purification , Ventilators, Mechanical/virology , COVID-19/epidemiology , COVID-19/virology , Equipment Reuse , Hospitals , Hot Temperature , Humans , Hydrogen Peroxide/pharmacology , SARS-CoV-2/genetics
4.
Am J Infect Control ; 49(4): 512-515, 2021 04.
Article in English | MEDLINE | ID: covidwho-866376

ABSTRACT

This study assessed the disinfection using 70% ethanol; H2O2-quaternary ammonium salt mixture; 0.1% sodium hypochlorite and autoclaving of four 3D-printed face shields with different designs, visor materials; and visor thickness (0.5-0.75 mm). We also investigated their clinical suitability by applying a questionnaire to health workers (HW) who used them. Each type of disinfection was done 40 times on each type of mask without physical damage. In contrast, autoclaving led to appreciable damage.


Subject(s)
COVID-19/prevention & control , Disinfectants/pharmacology , Disinfection/methods , Personal Protective Equipment/virology , Printing, Three-Dimensional , SARS-CoV-2 , COVID-19/epidemiology , Data Collection , Equipment Design , Ethanol/pharmacology , Health Personnel , Humans , Hydrogen Peroxide/pharmacology , Sodium Hypochlorite/pharmacology
5.
J Clin Virol ; 131: 104592, 2020 10.
Article in English | MEDLINE | ID: covidwho-726609

ABSTRACT

OBJECTIVES: We evaluated a rapid chromatographic immunoassay (IgG/IgM antibodies) and an ELISA assay to diagnose COVID-19 in patient sat two Brazilian hospitals. METHODS: A total of 122 subjects with COVID-19 were included: 106 SARS-COV-2 RT-PCR-positive patients and 16 RT-PCR-negative patients with symptoms and chest computed tomography (CT) consistent with COVID-19. Ninety-six historical blood donation samples were used as controls. Demographic and clinical characteristics were retrieved from electronic records. Sensitivity and specificity were calculated, as were their 95% binomial confidence intervals using the Clopper-Pearson method. All analyses were performed in R version 3.6.3. RESULTS: The sensitivity of the chromatographic immunoassay in all RT-PCR-positive patients, irrespective of the timing of symptom onset, was 85.8% (95% binomial CI 77.7% to 91.9%). This increased with time after symptom onset, and at >14 days was 94.9% (85.9% to 98.9%). The specificity was 100% (96.4% to 100%). 15/16 (94%) RT- PCR-negative cases tested positive. The most frequent comorbidities were hypertension and diabetes mellitus and the most frequent symptoms were fever, cough, and dyspnea. All RT-PCR-negative patients had pneumonia. The most frequent thoracic CT findings were ground glass changes (n = 11, 68%), which were bilateral in 9 (56%) patients, and diffuse reticulonodular infiltrates (n = 5, 31%). CONCLUSIONS: The COVID-19 rapid chromatographic immunoassay evaluated in this study had a high sensitivity and specificity using plasma, particularly after 14 days from symptom onset. ELISA and qualitative rapid chromatographic immunoassays can be used for the diagnosis of RT-PCR-negative patients.


Subject(s)
Antibodies, Viral/blood , Chromatography , Coronavirus Infections/diagnosis , Immunoassay , Pneumonia, Viral/diagnosis , Adult , Aged , Aged, 80 and over , Betacoronavirus , Brazil , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques , Coronavirus Infections/immunology , Female , Hospitalization/statistics & numerical data , Humans , Immunoglobulin G/blood , Male , Middle Aged , Pandemics , Pneumonia, Viral/immunology , Prospective Studies , SARS-CoV-2 , Sensitivity and Specificity , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL